Вы здесь: Главная Products Optical equipment Optical Receivers SDO3000 Series Optical Receiver
Действия с Документом

SDO3000 Series Optical Receiver

SDO3000 Series Optical Receiver
  • High output level
  • Electronic level adjustments
  • AGC system
  • Input optical and output electrical level indication
  • Wide range of input optical power
  • Built-in / electronic slope adjustment
  • Compact due-cast housing

Models

  • SDO3000 – single optical input
  • SDO3001 – single optical input, remote control system
  • SDO3002 – two optical inputs, remote control system
Specification

SDO3000
SDO3001
SDO3002
Frequency range
48 to 862 MHz
Bypass flatness
±0.75 dB
Output level (CTB/CSO < -60 dB, CENELEC 42 ch),
  • 9 dB slope
  • flat

  • 114 dBuV
  • 110 dBuV

  • 112 dBuV
  • 108 dBuV

  • 112 dBuV
  • 108 dBuV
Input optical wavelength
1200 to 1600 nm
Input optical power range
-8.5 to +3 dBm
Effective AGC range
-8 to +2 dBm
AGC modes
off / by input power
Optical return loss
45 dB
Equivalent input noise current
4,5 pA/√Hz
Level adjustment range
20 dB
Slope adjustment range
0/6/9 dB
(jumper)
20 dB
20 dB
Return loss
> 18 dB
RF connectors type
3/8” (F)
TAP attenuation
20 dB
Number of outputs
1
1
2
Optical connector type
SC/APC
HUM modulation
< -70 dB
Main powering voltage
~180 to 250 V (110V available)
Power consumption
12 W
8,5 W
9 W
Dimensions
165х155х60 mm
Weight
1.5 kg
Temperature range
-20 to +50 °С
Remote control
-
+
+

Built-in remote control allows transmitting optical receiver parameters to operator, and controlling the receiver via Ethernet.
Control interfaces
  • Remote control
  • Local control
  • Ethernet, 10/100Mbit
  • Manually by buttons
Supported network protocols
IP, UDP, DHCP, FTTP, SNMP, HTTP, Telnet, PLANAR Control Protocol


User interfaces and indication
Remote control
  • TelNet
  • Web-interface
  • SNMP protocol custom software
  • PLANAR protocol custom software
  • Standard SNMP browser
Local control
Manually controlling by using 3 built-in buttons
Indication
  • Multifunctional 3-digit indicator
  • Active optical input indicator
  • Power status indicator

Checked parameters and control
Max number of optical inputs
2
Measured input optical power
-11 to +3 dBm
Measured RF group signal*
80 to 120 dBuV
Receiver temperature0 to 100 °C
Supply power
5 to 15 V
Log volume
20000 events
Switching between inputs
  • Manual
  • Automatic
AGC modes
  • off
  • by input signal
Alarm circuit status
K1/K0 (open/closed)
Note: * - SENELEC, 42 ch.
 

Персональные инструменты